A A42MX36 device was tested at Brookhaven National Lab, using Chlorine ions. VCC was set to a nominal 5.0VDC. The device was statically biased for this test. Latchup was detected at an LET of 13.2 MeV-cm2/mg..
Device: 42MX36
Package: PQFP208
L/C: 2ACU533431
S/N: LAN4101
Bias Voltage: 5.0VDC.
Test Pattern: Static Bias
Ion used: 210 MeV Cl-35
| Device S/N | Run Number | VCC | Angle (Degrees) |
LET (MeV-cm2/mg) |
Latch | Fluence1 | Strip Chart |
LAN4101 |
8 | 5.0 | 60 | 22.9 | Yes | SL | LAN4101C1.pdf |
LAN4101 |
9 | 5.0 | 60 | 22.9 | Yes | ~105 | LAN4101C2.pdf |
LAN4101 |
10 | 5.0 | 45 | 16.2 | Yes | ~2.7 x 106 | LAN4101C3.pdf |
LAN4101 |
11 | 5.0 | 30 | 13.2 | Yes | ~106 | LAN4101C4.pdf |
LAN4101 |
12 | 5.0 | 0 | 11.4 | No | 107 | LAN4101C5.pdf |
1SL ::= Shutter Latch