Three FM1608 (Plastic Package) parts were tested at the Brookhaven National Labs'
Tandem Van de Graaff accelerator facility using Bromine at normal incidence and
energy of 244.4 MeV, yielding an LET of 38.1 MeV-cm2/mg and range of 32.2 um.
All three devices latched immediately upon shutter opening (run # 40 was aborted before
shutter opening due to operator error and disregarded). Because of the immediate low LET
latchup, cross-section information and latchup threshold were not measured. Device bias
was a nominal 5.0V for all runs, and each run was terminated almost immediately after the
shutter was opened and the device under test latched. A flux of approximately 1.7 x
104 ions/cm2 was used for all runs.
Package: Plastic DIP
D/C: 9826
L/C:
S/N: HOY11, HOY12, HOY13
| Device S/N | Run Number | VCC | Latch | Strip Chart |
HOY11 |
38 | 5.0 | Yes | HOY11B1.pdf |
HOY12 |
39 | 5.0 | Yes | HOY12B1.pdf |
HOY13 |
40 | 5.0 | Yes | Run terminated, operator error. |
HOY13 |
41 | 5.0 | Yes | HOY13B2.pdf |